Skip to main content
Tetra Inspection

AQL Chart and AQL Table: ANSI/ASQ Z1.4 Sampling Tables

An AQL chart is the pair of sampling tables from ANSI/ASQ Z1.4 and ISO 2859-1 that turns a lot size, an inspection level and an Acceptable Quality Limit into a sample size and an accept/reject number. This page reproduces the AQL table in full — the sample size code letters and the single sampling plans for normal inspection — and shows how to read it for a real shipment.

AQL Table 1: Sample Size Code Letters by Lot Size and Inspection Level

Find the row that contains your lot size, then read across to the inspection level named in your purchase order. General Inspection Level II is the default for consumer goods; Level I pulls a smaller sample and Level III a larger one. The special levels S-1 to S-4 are for costly or destructive checks where only a handful of units can be tested.

Lot or batch sizeGeneral inspection levelsSpecial inspection levels
IIIIIIS-1S-2S-3S-4
2 – 8AABAAAA
9 – 15ABCAAAA
16 – 25BCDAABB
26 – 50CDEABBC
51 – 90CEFBBCC
91 – 150DFGBBCD
151 – 280EGHBCDE
281 – 500FHJBCDE
501 – 1,200GJKCCEF
1,201 – 3,200HKLCDEG
3,201 – 10,000JLMCDFG
10,001 – 35,000KMNCDFH
35,001 – 150,000LNPDEGJ
150,001 – 500,000MPQDEGJ
500,001 and overNQRDEHK

Level II (highlighted) is the default general inspection level. The code letter, A to R, is the row to open in the AQL chart below.

AQL Sampling Plan Table: Single Sampling Plans for Normal Inspection

This is the AQL chart most buyers mean. Each row is a code letter with its sample size; each AQL column gives the accept number (Ac) and the reject number (Re). Accept the lot when the defects found in the sample are at or below Ac; reject it when they reach Re.

An arrow marks a cell where the standard defines no plan. Follow it to the first Ac/Re pair below (a larger sample) or above (a smaller sample) and use the sample size of that row as well. If the sample size reaches or exceeds the lot size, inspect every unit.

AQL for normal inspection table (ANSI/ASQ Z1.4 Table II-A)

Code letterSample sizeAcceptable Quality Limit (AQL)
0.0650.100.150.250.400.651.01.52.54.06.5
Ac / ReAc / ReAc / ReAc / ReAc / ReAc / ReAc / ReAc / ReAc / ReAc / ReAc / Re
A2↓↓↓↓↓↓↓↓↓↓0 / 1
B3↓↓↓↓↓↓↓↓↓0 / 1↓
C5↓↓↓↓↓↓↓↓0 / 1↓↓
D8↓↓↓↓↓↓↓0 / 1↓↓1 / 2
E13↓↓↓↓↓↓0 / 1↓↓1 / 22 / 3
F20↓↓↓↓↓0 / 1↓↓1 / 22 / 33 / 4
G32↓↓↓↓0 / 1↓↓1 / 22 / 33 / 45 / 6
H50↓↓↓0 / 1↓↓1 / 22 / 33 / 45 / 67 / 8
J80↓↓0 / 1↓↓1 / 22 / 33 / 45 / 67 / 810 / 11
K125↓0 / 1↓↓1 / 22 / 33 / 45 / 67 / 810 / 1114 / 15
L2000 / 1↓↓1 / 22 / 33 / 45 / 67 / 810 / 1114 / 1521 / 22
M315↓↓1 / 22 / 33 / 45 / 67 / 810 / 1114 / 1521 / 22↑
N500↓1 / 22 / 33 / 45 / 67 / 810 / 1114 / 1521 / 22↑↑
P8001 / 22 / 33 / 45 / 67 / 810 / 1114 / 1521 / 22↑↑↑
Q1,2502 / 33 / 45 / 67 / 810 / 1114 / 1521 / 22↑↑↑↑
R2,0003 / 45 / 67 / 810 / 1114 / 1521 / 22↑↑↑↑↑

AQL 2.5 (highlighted) is the most common limit for major defects and AQL 4.0 for minor defects. ↓ use the first plan below the arrow; ↑ use the first plan above the arrow.

Ac: accept the lot if defects are at or below this number. Re: reject at or above.

Tightened and reduced inspection (Tables II-B and II-C) are covered by the AQL calculator under its inspection severity setting.

How to Read the AQL Chart

Reading the AQL table takes three lookups: lot size to code letter, code letter to sample size, and sample size to the accept and reject numbers at your AQL.

  1. 1

    Find the code letter. In Table 1, locate the row for your lot size and read across to the inspection level.

  2. 2

    Find the sample size. In the AQL chart, the row for that code letter gives the number of units to pull at random from the lot.

  3. 3

    Read Ac and Re. In the same row, the column for your AQL gives the accept and reject numbers. Count the defects found in the sample and compare.

Worked example: lot of 5,000 units, Level II, AQL 2.5

A lot of 5,000 units falls in the 3,201 – 10,000 row of Table 1. At General Inspection Level II that row gives code letter L. In the AQL chart, code letter L means a sample of 200 units, and at AQL 2.5 the plan reads Ac 10, Re 11: the inspector pulls 200 units at random, the lot is accepted with 10 or fewer defects and rejected with 11 or more.

Garment AQL chart: AQL 2.5 major and AQL 4.0 minor

Apparel orders are usually inspected at General Level II with AQL 2.5 for major defects and AQL 4.0 for minor defects, and no critical defect is accepted. For a garment order of 3,000 pieces, Table 1 gives code letter K and the AQL chart gives a sample of 125 pieces. The lot is accepted with up to 7 major defects (rejected at 8) and up to 10 minor defects (rejected at 11). Both limits apply to the same 125 pieces, and exceeding either one rejects the lot.

MIL-STD-105E, ANSI/ASQ Z1.4 and ISO 2859-1: One AQL Table, Three Names

The AQL chart on this page follows ANSI/ASQ Z1.4, the American national standard for sampling by attributes. It descends from MIL-STD-105E, the United States military standard cancelled in 1995, and ISO 2859-1 is the international edition of the same system. For single sampling plans under normal inspection the three publish the same sample size code letters, sample sizes and accept/reject numbers, so a plan written against MIL-STD-105E or ISO 2859-1 reads from this AQL table without change. They differ in their switching rules between normal, tightened and reduced inspection, which is why a purchase order should name the standard it follows.

AQL Chart and AQL Table FAQ

What is an AQL chart?

An AQL chart is the set of sampling tables from ANSI/ASQ Z1.4 and ISO 2859-1 used in acceptance sampling. It converts a lot size and an inspection level into a sample size code letter, then gives the sample size and the accept (Ac) and reject (Re) numbers for each Acceptable Quality Limit. Inspectors use it to decide how many units to check and how many defects a lot may contain before it is rejected.

How do I read the AQL chart at AQL 2.5, Level II?

Find your lot size in Table 1 and read the General Level II column for the code letter, then open that row in the AQL chart and read the AQL 2.5 column. For a lot of 5,000 units, Level II gives code letter L, a sample of 200 units, accept on 10 defects and reject on 11. For a lot of 1,000 units it is code letter J, 80 units, Ac 5, Re 6.

How does the AQL table set the sample size?

The sample size depends on the lot size and the inspection level, not on the AQL. Table 1 maps the lot size and level to a code letter, and each code letter has a fixed sample size in the AQL chart, from 2 units at code letter A to 2,000 units at code letter R. The AQL then changes only the accept and reject numbers for that sample.

Is there a separate garment AQL chart?

No. Apparel uses the same ANSI/ASQ Z1.4 tables with the limits most buyers set for clothing: AQL 2.5 for major defects and AQL 4.0 for minor defects at General Inspection Level II, with no critical defects accepted. For 3,000 pieces that is code letter K, a sample of 125 pieces, up to 7 major and 10 minor defects.

AQL 1.0 vs 2.5 vs 4.0: what is the difference?

The AQL is the worst tolerable process average, in percent defective, when a continuing series of lots is submitted for acceptance sampling, so a lower AQL is stricter. The sample size does not change, only the accept number does: for a lot of 5,000 units at Level II the sample is 200 units, with Ac 5 at AQL 1.0, Ac 10 at AQL 2.5 and Ac 14 at AQL 4.0. Buyers typically use AQL 1.0 for high-value or safety-related products, 2.5 for major defects on general consumer goods and 4.0 for minor, cosmetic defects.

Should I use the AQL chart or the AQL calculator?

They give the same answer from the same tables. Use the AQL calculator when you have one lot and want the sample size and accept/reject numbers in a second, including tightened and reduced inspection. Use the AQL chart when you want to see every plan at once, compare AQL levels side by side, print the table for a purchase order, or check a figure an inspector or supplier has quoted.

What do the arrows in the AQL table mean?

An arrow marks a cell where the standard defines no plan for that sample size and AQL. Follow the arrow to the first accept/reject pair in that column, below the arrow for a larger sample or above it for a smaller one, and use the sample size of that row. If the sample size equals or exceeds the lot size, the whole lot is inspected.

Which standard is the AQL chart based on?

The AQL chart on this page follows ANSI/ASQ Z1.4, which carries the same single sampling plans for normal inspection as ISO 2859-1 and the cancelled MIL-STD-105E. Sample size code letters, sample sizes and accept/reject numbers are identical across the three for normal inspection; the switching rules differ.

Need the AQL chart applied to your next shipment?

Book a pre-shipment inspection and our inspectors sample to the AQL and inspection level you set.